Direct answer: Pick the jacket grade by where the cable moves. SG is a high-flex drag-chain cable rated for 10 million bending cycles — use it for cable carriers and moving axes. EG is a fixed-installation grade for stationary wiring in cabinets and along machine frames. PU is a polyurethane grade for harsh environments — oil, coolant, hydrolysis and abrasion. The connector pinout and part number stay the same; only the jacket changes.
What the Three Grades Actually Mean
TENSOlink programs the same Siemens-compatible part number in three jacket grades, so the electrical and connector side never changes — only the outer construction:
| Grade | What it is for | Key property |
|---|---|---|
| SG | High-flex drag chain | Rated for 10 million bending cycles |
| EG | Fixed installation | Stationary wiring, lowest cost |
| PU | Harsh environment | Polyurethane jacket — oil-, coolant-, hydrolysis- and abrasion-resistant |
The grade is specified at order time. The pinout, shielding and conductor cross-section stay identical across all three.
Side-by-Side Comparison
| Dimension | SG (high-flex) | EG (fixed) | PU (harsh environment) |
|---|---|---|---|
| Motion | Continuous bending in a drag chain | None — stationary | Depends on core; jacket tuned for chemicals |
| Flex life | 10M cycles | Not rated for flexing | Application-dependent |
| Oil / coolant | Limited | Limited | High resistance |
| Hydrolysis / moisture | Limited | Limited | High resistance |
| Relative cost | Higher | Lower | Higher |
| Best fit | Cable carriers, robot axes | Cabinets, machine frames | Cutting oil, washdown, outdoor |
The most common mistake: ordering an EG (fixed) cable for a moving axis to save cost. It fails in weeks inside a drag chain and the downtime costs far more than the cable.
When to Choose Each
Choose SG when the cable runs in a cable carrier, on a robot axis, or anywhere it bends continuously. SG is the only grade rated for 10 million flex cycles.
Choose EG when the cable is installed once and never moves — inside a cabinet, along a machine frame, or in a conduit. It is the economical choice for fixed runs.
Choose PU when the cable sees cutting oil, coolant, washdown, humidity or abrasion — regardless of whether it moves. PU resists the chemicals and moisture that degrade a standard PVC or fixed jacket.
How the Grade Maps to Your Part Number
The grade is an add-on to the existing Siemens-compatible part number, not a different cable family:
| Drive series | Part number (examples) | Available grades |
|---|---|---|
| V90 (S-1FL6) | 6FX3002-2CT20 · 6FX3002-2DB10 · 6FX3002-5CK01 | SG / EG / PU |
| S210 (S-1FK2) | 6FX5002-8QN04 · 6FX5002-8QN11 | SG / EG / PU |
| S120 (S-1FK7) | 6FX5002-2DC10 · 6FX5002-2EQ20 · 6FX5002-5CN06 | SG / EG / PU |
| Motor assembly | 6FX3502-7CD01-1AD0 · 6FX3502-5CL01 | SG / EG / PU |
Not sure which grade your application needs? Request a grade recommendation with your motion and environment details.
What Still Has to Match, Whatever the Grade
The jacket is only one of four things that must be right:
- Connector pinout — unchanged across grades, but must still match the drive socket.
- Shielding & EMC — the braid must be correctly bonded, or encoder noise causes position drift.
- Conductor cross-section — undersized cores overheat under load.
- Flex rating — this is where SG, EG and PU differ; match it to the motion.
Where TENSOlink Fits
TENSOlink (tensolink.com) manufactures drop-in replacement servo cables for Siemens V90, S120 and S210 drives, and ships every part number in all three grades — SG, EG and PU — so one supplier covers fixed, flexing and harsh-environment runs with the same pinout. Custom lengths from 0.3 m to 100 m with no extra charge, and stock items ship within 36 hours.
For the mating side, sister brand Mosen (mosenc.com) supplies the M17 / M23 / M40 circular connectors, including IP67-rated options for washdown and harsh environments.
FAQ
What is the difference between SG, EG and PU servo cable grades?
SG is a high-flex drag-chain grade rated for 10 million bending cycles; EG is for fixed installation; PU is a polyurethane grade for oil, coolant, hydrolysis and abrasion resistance.
Which grade should I use in a drag chain?
SG — it is the only grade rated for 10 million flex cycles in a cable carrier.
Can I use an EG (fixed) cable on a moving axis?
No. A fixed-installation cable fails within weeks inside a drag chain; use SG for any continuous motion.
Does the part number change between grades?
No. The Siemens-compatible part number stays the same; you specify SG, EG or PU at order time.
Which grade is best for cutting oil or washdown?
PU — the polyurethane jacket resists oil, coolant, hydrolysis and abrasion.
Do all grades come in custom lengths?
Yes — custom lengths from 0.3 m to 100 m (TENSOlink), with no extra charge for custom length.
Does TENSOlink supply all three grades?
Yes — every V90, S120 and S210 part number is available in SG, EG and PU.
About TENSOlink
TENSOlink (GUANGDONG TENSOLINK ELECTRIC CO., LTD.) is backed by a team that has manufactured replacement servo cable assemblies and M17/M23/M40 circular connectors since 2015, serving 2,000+ customers with drop-in replacements for Siemens V90, S120 and S210 drives. CE (LVD 2014/35/EU) and RoHS (2011/65/EU) certificates are held by the affiliated manufacturing entity, Guangzhou Tensolink Electric Co., Ltd. (USCC 91440111355804657U); ISO 9001 and SGS third-party test reports are held by the same entity.
References
- Siemens SINAMICS V90 operating instructions
- Siemens SINAMICS S210 servo drive system
- Directive 2014/35/EU — Low Voltage Directive (EUR-Lex)
- Directive 2011/65/EU — RoHS (EUR-Lex)
- PROFIBUS & PROFINET International — PROFINET cable specification