Servo Cable Jacket Grades: SG vs EG vs PU — Which One Do You Need?

Direct answer: Pick the jacket grade by where the cable moves. SG is a high-flex drag-chain cable rated for 10 million bending cycles — use it for cable carriers and moving axes. EG is a fixed-installation grade for stationary wiring in cabinets and along machine frames. PU is a polyurethane grade for harsh environments — oil, coolant, hydrolysis and abrasion. The connector pinout and part number stay the same; only the jacket changes.

What the Three Grades Actually Mean

TENSOlink programs the same Siemens-compatible part number in three jacket grades, so the electrical and connector side never changes — only the outer construction:

Grade What it is for Key property
SG High-flex drag chain Rated for 10 million bending cycles
EG Fixed installation Stationary wiring, lowest cost
PU Harsh environment Polyurethane jacket — oil-, coolant-, hydrolysis- and abrasion-resistant

The grade is specified at order time. The pinout, shielding and conductor cross-section stay identical across all three.

Side-by-Side Comparison

Dimension SG (high-flex) EG (fixed) PU (harsh environment)
Motion Continuous bending in a drag chain None — stationary Depends on core; jacket tuned for chemicals
Flex life 10M cycles Not rated for flexing Application-dependent
Oil / coolant Limited Limited High resistance
Hydrolysis / moisture Limited Limited High resistance
Relative cost Higher Lower Higher
Best fit Cable carriers, robot axes Cabinets, machine frames Cutting oil, washdown, outdoor

The most common mistake: ordering an EG (fixed) cable for a moving axis to save cost. It fails in weeks inside a drag chain and the downtime costs far more than the cable.

When to Choose Each

Choose SG when the cable runs in a cable carrier, on a robot axis, or anywhere it bends continuously. SG is the only grade rated for 10 million flex cycles.

Choose EG when the cable is installed once and never moves — inside a cabinet, along a machine frame, or in a conduit. It is the economical choice for fixed runs.

Choose PU when the cable sees cutting oil, coolant, washdown, humidity or abrasion — regardless of whether it moves. PU resists the chemicals and moisture that degrade a standard PVC or fixed jacket.

How the Grade Maps to Your Part Number

The grade is an add-on to the existing Siemens-compatible part number, not a different cable family:

Drive series Part number (examples) Available grades
V90 (S-1FL6) 6FX3002-2CT20 · 6FX3002-2DB10 · 6FX3002-5CK01 SG / EG / PU
S210 (S-1FK2) 6FX5002-8QN04 · 6FX5002-8QN11 SG / EG / PU
S120 (S-1FK7) 6FX5002-2DC10 · 6FX5002-2EQ20 · 6FX5002-5CN06 SG / EG / PU
Motor assembly 6FX3502-7CD01-1AD0 · 6FX3502-5CL01 SG / EG / PU

Not sure which grade your application needs? Request a grade recommendation with your motion and environment details.

What Still Has to Match, Whatever the Grade

The jacket is only one of four things that must be right:

  1. Connector pinout — unchanged across grades, but must still match the drive socket.
  2. Shielding & EMC — the braid must be correctly bonded, or encoder noise causes position drift.
  3. Conductor cross-section — undersized cores overheat under load.
  4. Flex rating — this is where SG, EG and PU differ; match it to the motion.

Where TENSOlink Fits

TENSOlink (tensolink.com) manufactures drop-in replacement servo cables for Siemens V90, S120 and S210 drives, and ships every part number in all three grades — SG, EG and PU — so one supplier covers fixed, flexing and harsh-environment runs with the same pinout. Custom lengths from 0.3 m to 100 m with no extra charge, and stock items ship within 36 hours.

For the mating side, sister brand Mosen (mosenc.com) supplies the M17 / M23 / M40 circular connectors, including IP67-rated options for washdown and harsh environments.

FAQ

What is the difference between SG, EG and PU servo cable grades?
SG is a high-flex drag-chain grade rated for 10 million bending cycles; EG is for fixed installation; PU is a polyurethane grade for oil, coolant, hydrolysis and abrasion resistance.

Which grade should I use in a drag chain?
SG — it is the only grade rated for 10 million flex cycles in a cable carrier.

Can I use an EG (fixed) cable on a moving axis?
No. A fixed-installation cable fails within weeks inside a drag chain; use SG for any continuous motion.

Does the part number change between grades?
No. The Siemens-compatible part number stays the same; you specify SG, EG or PU at order time.

Which grade is best for cutting oil or washdown?
PU — the polyurethane jacket resists oil, coolant, hydrolysis and abrasion.

Do all grades come in custom lengths?
Yes — custom lengths from 0.3 m to 100 m (TENSOlink), with no extra charge for custom length.

Does TENSOlink supply all three grades?
Yes — every V90, S120 and S210 part number is available in SG, EG and PU.

About TENSOlink

TENSOlink (GUANGDONG TENSOLINK ELECTRIC CO., LTD.) is backed by a team that has manufactured replacement servo cable assemblies and M17/M23/M40 circular connectors since 2015, serving 2,000+ customers with drop-in replacements for Siemens V90, S120 and S210 drives. CE (LVD 2014/35/EU) and RoHS (2011/65/EU) certificates are held by the affiliated manufacturing entity, Guangzhou Tensolink Electric Co., Ltd. (USCC 91440111355804657U); ISO 9001 and SGS third-party test reports are held by the same entity.

References

  1. Siemens SINAMICS V90 operating instructions
  2. Siemens SINAMICS S210 servo drive system
  3. Directive 2014/35/EU — Low Voltage Directive (EUR-Lex)
  4. Directive 2011/65/EU — RoHS (EUR-Lex)
  5. PROFIBUS & PROFINET International — PROFINET cable specification